Hoc AOX 380VAC 1/4 turn actus electrici usus 4-20mA, 0-10VDC ut significationibus moderandis, eligi potest ut 110V, 220V, 380V voltage, specialiter ad valvulas pilas, papilionem valvularum, valvularum obturaculum aliaque similia proposita. Ex divitis technicis theoriis et ubere experientiae, AOX unicam habet technicam scientiam-quam, quae est praecipua vis impellendi ad evolutionem et scientificam productionem dirigendi actus pro omnibus componentibus motoriis operatis. AOX anteposuitsupplierof multarum et magnarum conatum. AOX in primario comitatu in plectro automationi industriae technologiae provectae augetur.
Hoc AOX *380VAC 1/4 rursus actus electriciuti 4-20mA, 0-10VDC ut significationibus potestate, et eligi possunt ut 110V, 220V, 380V voltage, specialiter ad valvulas pila, papilionem valvularum, valvularum obturaculum et alia similia proposita. Ex divitis technicis theoriis et ubere experientiae, AOX unicam habet technicam scientiam-quam, quae est praecipua vis impellendi ad evolutionem et scientificam productionem dirigendi actus pro omnibus componentibus motoriis operatis. AOX anteposuitsupplierof multarum et magnarum conatum. AOX in primario comitatu in plectro automationi industriae technologiae provectae augetur.
Hoc AOX *380VAC 1/4 turn actus electrici ilate usus est in petroleo, chemica, aqua curatione, navigio, graphio, potentia herbarum, calefactione, levi industria et aliis industriis. Apta mutandi/modulatae pilae/obturaculi valvulae et impulsio absorber automation. AOX suum habet suumfactoryinChina.Since 1997, AOX omnem operam dedit ut clientes cum summa qualitate AOX praeberet.380VAC 1/4 vertere actus electriciet officia. Contendunt evolutionem industriae ducere et promovere per innovationem administrationem, technologiam evolutionis et humanae facultatis administrationem.
Model |
Max Output Torque |
60/50Hz Operans Tempus |
Max Coegi Shaft Location |
Potestas |
Ratum Currentï¼Aï¼ |
Manus rota Seditio |
Pondus |
|||
unum tempus |
tria tempora |
|||||||||
N·M |
90° |
mm |
W |
110V |
220V |
380V |
440V |
N |
Kg |
|
AOX-Q-005 |
50 |
18/22 |
Φ20 |
20 |
1.10/0.95 |
0.55/0.54 |
0.3/0.3 |
N/A |
10 |
7.5 |
AOX-Q-008 |
80 |
18/22 |
Φ20 |
20 |
1.10/0.95 |
0.55/0.54 |
0.3/0.3 |
N/A |
10 |
7.5 |
AOX-Q-010 |
100 |
18/22 |
Φ20 |
20 |
1.10/0.95 |
0.55/0.54 |
0.3/0.3 |
N/A |
10 |
7.5 |
AOX-Q-015 |
150 |
21/25 |
Φ20 |
40 |
1.65/1.67 |
0.88/0.84 |
0.31/0.31 |
0.30/0.31 |
11 |
17.3 |
AOX-Q-020 |
200 |
21/25 |
Φ20 |
40 |
1.67/1.67 |
0.89/0.85 |
0.31/0.31 |
0.30/0.31 |
11 |
17.3 |
AOX-Q-030 |
300 |
26/31 |
32 |
90 |
1.85/1.86 |
0.92/0.92 |
0.35/0.35 |
0.34/0.34 |
13.5 |
22 |
AOX-Q-050 |
500 |
26/31 |
32 |
120 |
3.60/3.62 |
1.55/1.58 |
0.59/0.59 |
0.58/0.58 |
13.5 |
23 |
AOX-Q-060 |
600 |
26/31 |
32 |
120 |
3.65/3.62 |
1.60/2.20 |
0.60/0.59 |
0.59/0.58 |
13.5 |
23 |
AOX-Q-080 |
800 |
31/37 |
40 |
180 |
4.10/4.10 |
2.15/2.20 |
0.85/0.85 |
0.79/0.79 |
16.5 |
29 |
AOX-Q-120 |
1200 |
31/37 |
40 |
180 |
4.20/4.10 |
2.35/2.30 |
0.87/0.87 |
0.81/0.81 |
16.5 |
29 |
AOX-Q-150 |
1500 |
78/93 |
40 |
120 |
3.65/3.62 |
1.60/2.20 |
0.60/0.59 |
0.59/0.58 |
40.5 |
77 |
AOX-Q-200 |
2000 |
93/112 |
40 |
180 |
4.10/4.10 |
2.15/2.20 |
0.85/0.85 |
0.79/0.79 |
49.5 |
83 |
AOX-Q-300 |
3000 |
93/112 |
40 |
180 |
4.20/4.10 |
2.35/2.30 |
0.87/0.87 |
0.81/0.81 |
49.5 |
83 |
AOX-Q-400 |
4000 |
155/185 |
40 |
180 |
4.20/4.10 |
2.35/2.30 |
0.87/0.87 |
0.81/0.81 |
82.5 |
83 |
AOX-Q-D |
5000 |
155/185 |
40 |
180 |
4.20/4.10 |
2.35/2.30 |
0.87/0.87 |
0.81/0.81 |
82.5 |
83 |
AOX-Q-600 |
6000 |
155/185 |
40 |
180 |
4.20/4.10 |
2.35/2.30 |
0.87/0.87 |
0.81/0.81 |
82.5 |
83 |
Torque rangeï¼50~6000N.m
Switching timeï¼22~185 S
Protectionï¼IP67, (IP68 ad libitum) Exdâ ¡CT5
Voltageï¼AC110~ 265V , AC / DC 24v Multi intentioni input
Unius periodi: AC220V / AC110V / AC24V / DC24V
Manual Overrideï¼Yes
Torques switch: Close / Open, sulum 1
Output signal(On-off type): Plene aperta & plene arcta passiva contactu (2A 250VAC).
Input/output signum (modulatum type:4-20mA(std configuratione); 0-10V & 2-10V libitum est.
Local Control Unit: Local control nodi of open/close/stop, switch nodo arcto control remote control/prohibit control(non-intrusive)
Exhibe modum: LCD, indicatio apertionis (0-100%) et aperta / proxima culpae
AOX'380VAC 1/4 rursus actus electricimaxime adhibetur in petroleo, curatione aquae, industria chemica, charta facienda, calefactione, vi electrica et aliis agris.
1.AOX380VAC 1/4 rursus actus electriciTerminal
-Spring onusta dis generis terminalis pro stricta wiring nexum sub gravi vibratione.
-Numerus terminationum sunt 22 pro utentibus.
-Terminal longitudo: 8-9mm
-Terminal size: 10×22×32
2.AOX380VAC 1/4 rursus actus electriciSpatium calefacientis
-Metal armaturae, calor ieiunium, vita longa, cum builtin temperatura transibit ne overheating.
-Core sealing sodales tellus nulla vitae metus ultrices.