Automatio electrici actus linearis cum positione tansmitter currente specialiter destinatur ad valvulas operating lineares sicut valvae globi similesque usus. AOX asupplierto multae et magnae conatibus. AOX actuator linearis automation electrici cum positione currenti tansmitter toto orbe serviunt, inter Europam, Americam, ICAO, Australiam, Africam, Asiam, in Medio Oriente et Southeast Asia. Late adhibetur in curatione aquae, calefactione, petrolei, industria chemica, electronicis, levi industria, cibo, medicina, textile, charta confectione, hydropower, navibus, excoquendis, novis energiae aliisque agris. Multas praeterea Fortuna D societates amicitias instituit.
Automation electrica lineares actus currentis positionis tansmitterspecialiter ad valvulas operating lineares ordinatur sicut valvae globi et usus similes. AOX est supplementum multis magnisque inceptis.AOX'sAutomation electrica lineares actus currentis positionis tansmittertoto orbe terrarum serviunt, inter Europam, Americam, ICAO, Australiam, Africam, Asiam, Orientem Medium et Southeast Asia. Late adhibetur in curatione aquae, calefactione, petrolei, industria chemica, electronicis, levi industria, cibo, medicina, textile, charta confectione, hydropotentia, navibus, excoquendis, novis energiae aliisque agris. Multas praeterea Fortuna D societates amicitias instituit.
Automation electrica lineares actus currentis positionis tansmitterapta modulandi et aperta arcto officio moderandi ac technologiae processus ad valvulas regendas operandas. AOX effector electrica Sinensium fabricator est. AOX porttitor producti notiones conceptus et fructus in applicationibus practicis multam attentionem et recognitionem acceperunt.Automation electrica lineares actus currentis positionis tansmittercerta, tuta et opportuna, commoda convenientiae et usui.
Model |
Thrust |
Celeritas |
Max itinerantur |
potentia |
Ratum current(A) |
Pondus |
N |
mm/S |
mm |
W |
220V/50HZ/1PH |
Kg |
|
AOX-L-30 |
3000 |
1.5 |
25 |
30 |
0.31 |
17.5 |
AOX-L-50 |
5000 |
1.5 |
40 |
45 |
0.42 |
19 |
AOX-L-80 |
8000 |
1.5 |
60 |
60 |
0.62 |
19.5 |
AOX-L-100 |
10000 |
1.5 |
100 |
60 |
0.68 |
33 |
AOX-L-160 |
16000 |
1.5 |
100 |
90 |
0.85 |
33 |
AOX-L-200 |
20000 |
1.5 |
100 |
90 |
0.87 |
33 |
AOX-L-250 |
25000 |
1.5 |
100 |
120 |
1.22 |
33 |
AOX-L-300 |
30000 |
1.5 |
100 |
120 |
1.28 |
33 |
Force range: 3000 - 300000 N
Cursus velocitatum: 1.5 mm/s
Motor Specifications: Classis F, protector scelerisque usque ad +135 °C (+275 °F)
Systema opus
On-off Type: S2 - 15 min, no more than 600 times per hour start
Modulans Type: S4 - 50%, usque ad 600 triggers per hora
In / off generis signum:
Input : AC 110/220 Input
Signum videre: Integratae culpae contactus, Claude valvae contactum, Aperi contactus valvae
Princeps corrosio resistentia
Coactus SWITCH PB / Limit Switch
Provide amplis voltage
Foedus internus
Locus imperium / auto hold
Phase ordo praesidium
Modular design
Conditionalis imperium praesidium
1.Terminal scandalum automation electrica lineares actus current situ tansmittr
In thalamo separato wiring inauguratus est, utens verno auto-typo terminali ut robustus et firmus.
2.Valve nexum
Per diversas bracket nexus, diversis valvis aptum esse potest. Utens immaculatam ferro scalam rectorem et lapsus ferro immaculatam.
3.Scale mensam
Mensa scalaAutomation electrica lineares actus currentis positionis tansmitterin rectore virgae instituitur, quae magis intuitiva et opportuna observatur.